PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Front view with USB Plug
Learn more

PTH200

All-in-one USB temperature sensor, with relative humidity and atmospheric pressure sensors
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificate
  • RoHS 3 compliant
Dracal_PTH420_Back_Unique_Serial_Number PTH420: USB-connected precision (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument (sensor) - Front view with cable
Learn more

PTH420

Precision USB Temperature, Relative Humidity and Atmospheric Pressure Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.1°C
Relative humidity 0 %RH to 100 %RH ±1.5 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
PTH450: Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument with USB connection, particle filter and aluminum tip for harsh environments.
Learn more

PTH450

Robust, High Precision USB Temperature, Humidity and Air Pressure Sensor
Typical operating range and precision
Temperature -40°C to 125°C ±0.1°C
Relative humidity 0 %RH to 100 %RH ±1.5 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminium external protection

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode option
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
RTD200: USB adapter for any Pt-100 RTD probe for temperature measurement - With Pt100 probe RTD200: USB adapter for any Pt-100 RTD probe for temperature measurement - Front view
Learn more

RTD200

2/3-wire RTD Probe to USB Adapter
Supports 2 and 3 wire PT100 RTD sensors
Temperature Operating range: -200°C to +800°C
Accuracy: ±0.06°C or better (at 25°C)
Resolution: ±0.02°C (typical)
Drift: <1%/year

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
RTD223 RTD to USB adapter with connected RTD Sillicon Sensor - zoomed
Learn more

RTD223

2/3-wire RTD Probe to USB Adapter
Supports 2 and 3 wire PT100 RTD sensors
Temperature Operating range: -200°C to +800°C
Accuracy: ±0.06°C or better (at 25°C)
Resolution: ±0.02°C (typical)
Drift: <1%/year

Supports 2 and 3 wire Pt100 RTD sensors
Temperature calculation using the DIN 43760 coefficients

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
RTD300: USB adapter for any Pt100 RTD probe for temperature measurement - With Pt100 probe RTD300: USB adapter for any Pt-100 RTD probe for temperature measurement - Front view - With connector
Learn more

RTD300

Enhanced Precision 2/3-wire RTD Probe to USB Adapter
Supports 2 and 3 wire PT100 RTD sensors
Temperature Operating range: -200°C to +800°C
Accuracy: ±0.005°C (at 25°C)
Accuracy: ±0.018°C (0°C to 50°C)
Resolution: ±0.0001°C (typical)
Noise level: ±0.0015°C ( at 25°C)
Drift: 0.007°C ±0.003°C/year (at 25°C and 45%RH)

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
BAR20 - Dracal USB-connected atmospheric pressure (barometer) sensor - Back view - Unique Serial Number BAR20 - Dracal USB-connected atmospheric pressure (barometer) sensor - Front view
Learn more

BAR20

USB Precision Barometer
Typical operating range and precision
Operating range 1 à 120 kPa (10 à 1200 mbar)
Accuracy ±0.15 kPa à 25°C (1.5 mbar)
Resolution 0.0065 kPa (0.065 mbar)

Internal temperature readings for compensation purposes

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor, particle filter and aluminum tip for harsh environments - Front view with USB plug TRH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor, particle filter and aluminum tip for harsh environments - Front View with cable.
Learn more

TRH450

Robust, high-precision USB temperature sensor with relative humidity
Typical operating range and precision
Temperature -40°C to 125°C ±0.1°C
Relative humidity 0 to 100 %RH ±1.5 %RH

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminium external protection

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH420: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor - Front View with cable. TRH420: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor - Front View with USB plug
Learn more

TRH420

Precision USB Temperature and Relative Humidity Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.1°C
Relative humidity 0 to 100 %RH ±1.5 %RH

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH320: Temperature and relative humidity USB sensor - Front view TRH320: Temperature and relative humidity USB sensor - Front View with USB plug
Learn more

TRH320

USB Temperature and Relative Humidity Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH200: USB Temperature and Relative Humidity Sensor With Exposed End - Zoomed End TRH200: USB Temperature and Relative Humidity Sensor With Exposed End - USB Plug and End
Learn more

TRH200

USB Temperature and Relative Humidity Sensor With Exposed End
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH

Protection

  • Exposed sensor

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificate
  • RoHS 3 compliant
Dracal CO2 reader DXC220 with short temperature and relative humidity probe (USB connector view) Dracal CO2 reader DXC220 (USB connector view)
Learn more

DXC220

USB Carbon Dioxide (CO2) Sensor, 20%
Typical operating range and precision
Carbon dioxide (CO2): 0-20 % ±70 ppm ±5% of reading
Temperature: 0°C to 45°C
Humidity: 0 %RH to 100 %RH
Probe temperature: -40°C to 70°C ±0.3°C
Probe humidity : 0 %RH to 100 %RH ±2.0 %RH

Additional information

  • Free data acquisition toolkit
  • Traceable to the CNRC certificates
Learn more

TMC100

USB temperature converter for thermocouple
Operating Range Accuracy
TMC100k: -200°C to 1372°C ±0.5°C or better
TMC100j: -200°C to 1200°C ±1.0°C or better
TMC100t: -200°C to +400°C ±0.5°C or better
TMC100n: -200°C to +1300°C ±0.5°C or better
TMC100e: -200°C to +1000°C ±0.5°C or better
Resolution: 0.0625°C
Error status code: No
  • Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
  • Built-in cold junction compensation
  • Follows NIST ITS-90 thermocouple temperature correction table

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TMC100: USB adapter for type-K thermocouple for temperature measurement - Front view - With connected connector
Learn more

TMC200

High-precision and high-resolution USB adapter for thermocouples of type K, J, T, N, or E
Operating Range Accuracy
TMC200k: -200°C to 1372°C ±0.5°C or better
TMC200j: -200°C to 1200°C ±1.0°C or better
TMC200t: -200°C to +400°C ±0.5°C or better
TMC200n: -200°C to +1300°C ±0.5C or better
TMC200e: -200°C to +1000°C ±0.5°C or better
Resolution: 0.01°C
Error status code: Yes
  • Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
  • Built-in cold junction compensation
  • Follows NIST ITS-90 thermocouple temperature correction table

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
VOC100 - Dracal USB-connected as sensor volatile organic compound (VOC), temperature and relative humidity - Back view - Unique Serial Number VOC100 - Dracal USB-connected as sensor volatile organic compound (VOC), temperature and relative humidity - Front view with USB plug
Learn more

VOC100

USB VOC, Temperature and Relative Humidity Sensor
Typical operating range and precision
Volatile Organic Compounds 0 to 32,768 ppb Semi-Quantitative
Temperature -40°C to 70°C ±0.3°C
Relative humidity 10 %RH to 95 %RH ±2.0 %RH

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode