PTH200
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificate
- RoHS 3 compliant


PTH420
Temperature | -40°C to 70°C | ±0.1°C |
Relative humidity | 0 %RH to 100 %RH | ±1.5 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


PTH450
Temperature | -40°C to 125°C | ±0.1°C |
Relative humidity | 0 %RH to 100 %RH | ±1.5 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Protection
- Internal filter efficiency: >99.99% of particles as small as 200 nm
- Compact aluminium external protection
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode option
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant

RS232-Tenki
RS232 Barometer
Range: | 15 to 115 kPa | |
Accuracy: | 2% MV Max from 0° to 85°C | |
Resolution: | ±0.1 kPa |
Communication protocol: RS-232


RTD200
Temperature | Operating range: | -200°C to +800°C |
Accuracy: | ±0.06°C or better (at 25°C) | |
Resolution: | ±0.02°C (typical) |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


RTD223
Temperature | Operating range: | -200°C to +800°C |
Accuracy: | ±0.06°C or better (at 25°C) | |
Resolution: | ±0.02°C (typical) |
Supports 2 and 3 wire Pt100 RTD sensors
Temperature calculation using the DIN 43760 coefficients
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


RTD300
Temperature | Operating range: | -200°C to +800°C |
Accuracy: | ±0.005°C (at 25°C) | |
Accuracy: | ±0.018°C (0°C to 50°C) | |
Resolution: | ±0.0001°C (typical) | |
Noise level: | ±0.0015°C ( at 25°C) |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


RTD_23
Operating range | -200°C to +800°C | |
Accuracy | ±0.06°C (at 25°C) | |
Resolution | ±0.02°C (typical) |
Supports 2 and 3 wire Pt100 RTD sensors
Temperature calculation using the DIN 43760 coefficients
Additional information
- Free data acquisition toolkit
- Traceable to the CNRC certificates
- RoHS 3 compliant


TRH450
Temperature | -40°C to 125°C | ±0.1°C |
Relative humidity | 0 to 100 %RH | ±1.5 %RH |
Protection
- Internal filter efficiency: >99.99% of particles as small as 200 nm
- Compact aluminium external protection
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TRH420
Temperature | -40°C to 70°C | ±0.1°C |
Relative humidity | 0 to 100 %RH | ±1.5 %RH |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TRH320
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TRH200
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Protection
- Exposed sensor
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificate
- RoHS 3 compliant


DXC220
Carbon dioxide (CO2): | 0-20 % | ±70 ppm ±5% of reading |
Temperature: | 0°C to 45°C | |
Humidity: | 0 %RH to 100 %RH | |
Probe temperature: | -40°C to 70°C | ±0.3°C |
Probe humidity : | 0 %RH to 100 %RH | ±2.0 %RH |
Additional information
- Free data acquisition toolkit
- Traceable to the CNRC certificates


TMC200k
Operating range | -200°C to 1372°C | |
Accuracy | ±0.5 °C at 25°C, ±1.5°C (25°C to 45°C) | |
Resolution | 5×10-5°C (typical) |
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
- Error status code
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMC100k
Operating range | -200°C to 1372°C | |
Accuracy | ±1.5°C or better |
- Supports type-K thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMC100t
USB Adapter for Type-T Thermocouples
Operating range | -200°C to +400°C | |
Accuracy | ±0.5°C or better |
- Supports type-T thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMC100n
USB Adapter for Type-N Thermocouple
Operating range | -200°C to +1300°C | |
Accuracy | ±1.0°C or better |
- Supports type-N thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMC100e
USB Adapter for Type-E Thermocouple
Operating range | -100°C to +1000°C | |
Accuracy | ±0.5°C or better |
- Supports type-E thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMC100j
Operating range | -100°C to 1200°C | |
Accuracy | ±1.0°C or better |
- Supports type-J thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMP125
Operating range: | -55°C[1] to +75°C | |
Accuracy: | ±1.0°C (max.) from -10 to +75°C | |
±2.0°C (max.) from -55 to +75°C | ||
Resolution: | 0.5°C |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- RoHS 3 compliant


VOC100
Volatile Organic Compounds | 0 to 32,768 ppb | Qualitative |
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 10 %RH to 95 %RH | ±2.0 %RH |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode


CONN-RTD-3PM
3-pin Miniature Connector for 2/3-wire RTD
Contact material: | Copper (CU) | |
Polarized: | Yes | |
Maximum temperature: | Up to 180°C |


Miniature male thermocouple connector
Flat 2-pin miniature connectors for types K,J,N,T and E thermocouples.
Contact type | Flat, compensated | |
Wiring style | Screw terminals, accepts wires up to 0.6 mm (AWG 22) | |
Polarized | Yes | |
Maximum operating temperature | Up to 180°C |


Ready-made pre-wired thermocouple probe
Response time: | ≤ 1 second | |
Length: | 1.5 m (5 ft) | 3 m (10 ft) |
Insulation: | Teflon | |
Type: | Bare welded point | |
Temperature range | Type dependent | (See Charasteristics) |
Compatible with Dracal Technologies TMC series thermocouple adapters


RTD-PT100-SIL
Temperature operating range: | -200°C to 200°C | |
Accuracy | At 0°C: | ±0.10°C |
From -25°C to +25°C: | ±0.15°C | |
From -50°C to +50°C: | ±0.18°C | |
From -100°C to +100°C: | ±0.27°C | |
From -200°C to +200°C: | ±0.43°C | |
Material: | Stainless steel probe | |
Silicon cable |
Compatible with our RTD converters
RoHS 3 compliant


I2C-M8-TRH320
I2C Temperature and Humidity Probe with an M8 Connector (12, 100 or 180 cm)
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Available lengths: 12, 100 cm and 180 cm
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Compatible with our DXC220 CO2 sensor


I2C-TRH Series
Pre-wired I2C Temperature and Humidity Probe for OEM Applications
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH |
Length: 100 cm, 180 cm
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm