PTH200
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificate
- RoHS 3 compliant


PTH420
Temperature | -40°C to 70°C | ±0.1°C |
Relative humidity | 0 %RH to 100 %RH | ±1.5 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


PTH450
Temperature | -40°C to 125°C | ±0.1°C |
Relative humidity | 0 %RH to 100 %RH | ±1.5 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Protection
- Internal filter efficiency: >99.99% of particles as small as 200 nm
- Compact aluminium external protection
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode option
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant

RS232-Tenki
RS232 Barometer
Range: | 15 to 115 kPa | |
Accuracy: | 2% MV Max from 0° to 85°C | |
Resolution: | ±0.1 kPa |
Communication protocol: RS-232


RTD200
Temperature | Operating range: | -200°C to +800°C |
Accuracy: | ±0.06°C or better (at 25°C) | |
Resolution: | ±0.02°C (typical) | |
Drift: | <1%/year |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


RTD223
Temperature | Operating range: | -200°C to +800°C |
Accuracy: | ±0.06°C or better (at 25°C) | |
Resolution: | ±0.02°C (typical) | |
Drift: | <1%/year |
Supports 2 and 3 wire Pt100 RTD sensors
Temperature calculation using the DIN 43760 coefficients
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


RTD300
Temperature | Operating range: | -200°C to +800°C |
Accuracy: | ±0.005°C (at 25°C) | |
Accuracy: | ±0.018°C (0°C to 50°C) | |
Resolution: | ±0.0001°C (typical) | |
Noise level: | ±0.0015°C ( at 25°C) | |
Drift: | 0.007°C ±0.003°C/year (at 25°C and 45%RH) |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


RTD_23
Temperature | ||
Operating range | -200°C to +800°C | |
Accuracy | ±0.06°C (at 25°C) | |
Resolution | ±0.02°C (typical) |
Supports 2 and 3 wire Pt100 RTD sensors
Temperature calculation using the DIN 43760 coefficients
Additional information
- 3-point calibration and VCP options not available.
- Free data acquisition toolkit
- Traceable to the CNRC certificates
- RoHS 3 compliant


BAR20
Operating range | 1 à 120 kPa (10 à 1200 mbar) | |
Accuracy | ±0.15 kPa à 25°C (1.5 mbar) | |
Resolution | 0.0065 kPa (0.065 mbar) |
Internal temperature readings for compensation purposes
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


BAR20-N
Operating range: | 1 to 120 kPa (10 to 1200 mbar) | |
Accuracy: | ±0.15 kPa at 25°C (1.5 mbar) |
Communication: USB-connected Virtual COM port
Sentence output formats: MDA and XDR NMEA
Additional information
Not supported by our data integration and acquisition tools
RoHS 3 compliant


TRH450
Temperature | -40°C to 125°C | ±0.1°C |
Relative humidity | 0 to 100 %RH | ±1.5 %RH |
Protection
- Internal filter efficiency: >99.99% of particles as small as 200 nm
- Compact aluminium external protection
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TRH420
Temperature | -40°C to 70°C | ±0.1°C |
Relative humidity | 0 to 100 %RH | ±1.5 %RH |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TRH320
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TRH200
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Protection
- Exposed sensor
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificate
- RoHS 3 compliant


DXC120
Carbon dioxide (CO2) | 400 to 10,000 ppm | ± (30 ppm + 3%MV) |
Additional information
- Free data acquisition toolkit
- Integrated self-calibration mechanism
- Manual calibration mechanism
- VCP mode


DXC220
Carbon dioxide (CO2): | 0-20 % | ±70 ppm ±5% of reading |
Temperature: | 0°C to 45°C | |
Humidity: | 0 %RH to 100 %RH | |
Probe temperature: | -40°C to 70°C | ±0.3°C |
Probe humidity : | 0 %RH to 100 %RH | ±2.0 %RH |
Additional information
- Free data acquisition toolkit
- Traceable to the CNRC certificates


TMC100
Operating Range | Accuracy | |
TMC100k: | -200°C to 1372°C | ±0.5°C or better |
TMC100j: | -200°C to 1200°C | ±1.0°C or better |
TMC100t: | -200°C to +400°C | ±0.5°C or better |
TMC100n: | -200°C to +1300°C | ±0.5°C or better |
TMC100e: | -200°C to +1000°C | ±0.5°C or better |
Resolution: | 0.0625°C | |
Error status code: | No |
- Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMC200
Operating Range | Accuracy | |
TMC200k: | -200°C to 1372°C | ±0.5°C or better |
TMC200j: | -200°C to 1200°C | ±1.0°C or better |
TMC200t: | -200°C to +400°C | ±0.5°C or better |
TMC200n: | -200°C to +1300°C | ±0.5C or better |
TMC200e: | -200°C to +1000°C | ±0.5°C or better |
Resolution: | 0.01°C | |
Error status code: | Yes |
- Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


TMP125
Operating range: | -55°C to +75°C | |
Accuracy: | ±1.0°C (max.) from -10 to +75°C | |
±2.0°C (max.) from -55 to +75°C | ||
Resolution: | 0.5°C |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- RoHS 3 compliant


SPECTRUM100
Ambient and white light
Range 0.0072 to 120,000 lx
Resolution 0.0036 lx per step
Colour and Infrared light
Range 0 to 20,000 lx
Resolution Up to 20 bits
Ultraviolet A and B light
UVA responsivity 0.93 counts/uW/cm2
UVB responsivity 2.1 counts/uW/cm2
Resolution 16 bits (65,536 counts)
Additional information
- Free data acquisition toolkit


USB-I2C-SPS30
Communication: I2C to USB
I2C speed: 400 kHz
Operating temperature range: 0°C to 70°C
Operating relative humidity range (non-condensing): 10 to 90 %RH
Additional information
- Free data acquisition toolkit


VOC100
Volatile Organic Compounds | 0 to 32,768 ppb | Semi-Quantitative |
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 10 %RH to 95 %RH | ±2.0 %RH |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode


DracalView


Ready-made pre-wired thermocouple probe
Response time: | ≤ 1 second | |
Length: | 1.5 m (5 ft) | 3 m (10 ft) |
Insulation: | Teflon | |
Type: | Bare welded point | |
Temperature range | Type dependent | (See Charasteristics) |
Compatible with Dracal Technologies TMC series thermocouple adapters