PTH450: Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument with USB connection, particle filter and aluminum tip for harsh environments - Front view with USB plug
Learn more

PTH450

Robust, high precision USB temperature, humidity and air pressure sensor
Typical operating range and precision
Temperature (°C): -40 to 125 ±0.1
Relative humidity (%RH): 0 to 100 ±1.5
Atmospheric pressure (kPa)
At 25 °C: 70 to 110 ±0.15
From 10 to 40°C: 70 to 110 ±0.18
From 0 to 40°C: 45 to 110 ±0.20
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminum external protection
Dracal_PTH420_Back_Unique_Serial_Number PTH420: USB-connected precision (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument (sensor) - Front view with cable
Learn more

PTH420

Precision USB temperature, relative humidity and atmospheric pressure sensor
Typical operating range and precision
Temperature (°C): -40 to 70 ±0.1
Relative humidity (%RH): 0 to 100 ±1.5
Atmospheric pressure (kPa)
At 25 °C: 70 to 110 ±0.15
From 10 to 40°C: 70 to 110 ±0.18
From 0 to 40°C: 45 to 110 ±0.20
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm
PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Front view with USB Plug
Learn more

PTH200

All-in-one USB temperature sensor, with relative humidity and atmospheric pressure sensors
Typical operating range and precision
Temperature (°C): -40 to 70 ±0.3
Relative humidity (%RH): 0 to 100 ±2.0
Atmospheric pressure (kPa)
At 25°C: 70 to 110 ±0.15
From 10 to 40°C: 70 to 110 ±0.18
From 0 to 40°C: 45 to 110 ±0.20
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm
TRH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor, particle filter and aluminum tip for harsh environments - Front view with USB plug TRH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor, particle filter and aluminum tip for harsh environments - Front View with cable.
Learn more

TRH450

Robust, high-precision USB temperature sensor with relative humidity
Typical operating range and precision
Temperature (°C): -40 to 125 ±0.1
Relative humidity (%RH): 0 to 100 ±1.5
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminum external protection
TRH420: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor - Front View with cable. TRH420: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor - Front View with USB plug
Learn more

TRH420

Precision USB temperature and relative humidity sensor
Typical operating range and precision
Temperature (°C): -40 to 70 ±0.1
Relative humidity (%RH): 0 to 100 ±1.5
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm
TRH320: Temperature and relative humidity USB sensor - Front view TRH320: Temperature and relative humidity USB sensor - Front View with USB plug
Learn more

TRH320

USB temperature and relative humidity sensor
Typical operating range and precision
Temperature (°C): -40 to 70 ±0.3
Relative humidity (%RH): 0 to 100 ±2.0
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm
TRH200: USB Temperature and Relative Humidity Sensor With Exposed End - USB Plug and End
Learn more

TRH200

USB temperature and relative humidity sensor with exposed end
Typical operating range and precision
Temperature (°C): -40 to 70 ±0.3
Relative humidity (%RH): 0 to 100 ±2.0
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • Exposed sensor
TMC100: USB adapter for type-K thermocouple for temperature measurement - Front view - With connected connector
Learn more

TMC200

High-precision and high-resolution USB adapter for thermocouple
Model Operating Range (°C ) Minimum Accuracy (°C)
TMC200k: -200 to 1372 ±0.5
TMC200j: -200 to 1200 ±1.0
TMC200t: -200 to +400 ±0.5
TMC200n: -200 to +1300 ±0.5
TMC200e: -200 to +1000 ±0.5
Resolution: 0.01°C
Error status code: Yes
  • Returns error status
  • Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
  • Built-in cold junction compensation
  • Follows NIST ITS-90 thermocouple temperature correction table
  • RoHS3 Compliant
Learn more

TMC100

USB temperature converter for thermocouple type K, J, N, E or T
Model Operating Range (°C ) Minimum Accuracy (°C)
TMC100k: -200 to 1372 ±0.5
TMC100j: -200 to 1200 ±1.0
TMC100t: -200 to +400 ±0.5
TMC100n: -200 to +1300 ±0.5
TMC100e: -200 to +1000 ±0.5
Resolution: 0.0625°C
Error status code: No
  • Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
  • Built-in cold junction compensation
  • Follows NIST ITS-90 thermocouple temperature correction table
  • RoHS3 Compliant
RTD300: USB adapter for any Pt100 RTD probe for temperature measurement - With Pt100 probe RTD300: USB adapter for any Pt-100 RTD probe for temperature measurement - Front view - With connector
Learn more

RTD300

Enhanced precision 2/3-wire RTD probe to USB adapter
Temperature
Operating range: -200 to +800°C
Accuracy (at 25°C): ±0.005°C
Accuracy (0 to 50°C): ±0.018°C
Resolution (typical): ±0.0001°C
Noise level (at 25°C): ±0.0015°C
Drift (at 25°C and 45%RH): 0.007 ± 0.003°C/year
  • Supports 2 and 3-wire Pt100 RTD sensors
  • Temperature calculation using the DIN 43760 coefficients
  • RoHS3 compliant
RTD200: USB adapter for any Pt-100 RTD probe for temperature measurement - With Pt100 probe RTD200: USB adapter for any Pt-100 RTD probe for temperature measurement - Front view
Learn more

RTD200

2/3-wire RTD probe to USB adapter
Temperature
Operating range: -200 to +800°C
Accuracy (at 25°C): ±0.06°C or better
Resolution (typical): ±0.02°C
Drift: <1%/year
  • Supports 2 and 3-wire Pt100 RTD sensors
  • Temperature calculation using the DIN 43760 coefficients
  • RoHS3 and CE compliant
RTD223 RTD to USB adapter with connected RTD Sillicon Sensor - zoomed
Learn more

RTD223

2/3-wire RTD probe to USB adapter with terminal block
Temperature
Operating range: -200 to +800°C
Accuracy (at 25°C): ±0.06°C or better
Resolution (typical): ±0.02°C
Drift: <1%/year
  • Supports 2 and 3-wire Pt100 RTD sensors
  • Temperature calculation using the DIN 43760 coefficients
  • RoHS3 and CE compliant
BAR20 - Dracal USB-connected atmospheric pressure (barometer) sensor - Back view - Unique Serial Number BAR20 - Dracal USB-connected atmospheric pressure (barometer) sensor - Front view
Learn more

BAR20

USB precision barometer
Atmospheric pressure
Operating range: 1 à 120 kPa (10 à 1200 mbar)
Accuracy (at 25°C): ±0.15 kPa (1.5 mbar)
Resolution: 0.0065 kPa (0.065 mbar)
  • User-accessible internal temperature reading (for calibration purposes)
  • RoHS3 and CE compliant
BAR20-N - Dracal USB-connected atmospheric pressure (barometer) sensor with NMEA output - Back view - Unique Serial Number BAR20-N - Dracal USB-connected atmospheric pressure (barometer) sensor with NMEA output - Front view
Learn more

BAR20-N

Precision barometer with NMEA output
Atmospheric pressure
Operating range: 1 to 120 kPa (10 to 1200 mbar)
Accuracy (at 25°C): ±0.15 kPa (1.5 mbar)
  • Communication: USB-connected Virtual COM port
  • Sentence output formats: MDA and XDR NMEA
  • RoHS3 and CE compliant

Not supported by our data integration and acquisition tools

RS232-Tenki: Dracal RS232 barometer
Learn more

RS232-Tenki

RS-232 barometer
Pressure
Range: 15 to 115 kPa
Accuracy: 2% MV Max from 0° to 85°C
Resolution: ±0.1 kPa

Communication protocol: RS-232

Dracal CO2 reader DXC220 with short temperature and relative humidity probe (USB connector view) Dracal CO2 reader DXC220 (USB connector view)
Learn more

DXC220

USB carbon dioxide (CO2) sensor, 20%
Typical operating range and precision
Carbon dioxide (CO2): 0-20 % ±70 ppm ±5% of reading
Temperature (°C): -40 to 70 ±0.3
Relative humidity (%RH): 0 to 100 ±2.0
DXC120: Dracal USB connected gas sensor for indoor level carbon dioxide (CO2) detection - Side view DXC120: Dracal USB connected gas sensor for indoor level carbon dioxide (CO2) detection - Front view
Learn more

DXC120

Small calibratable USB carbon dioxide (CO2) sensor
Typical operating range and precision
Carbon dioxide (CO2) 400 to 10,000 ppm ± (30 ppm + 3%MV)
TMP125 USB Temperature Sensor, with cable TMP125 USB Temperature Sensor
Learn more

TMP125

USB ambient temperature sensor
Temperature
Operating range (°C): -55 to 75
Accuracy (°C)
From -10 to +75°C: ±1.0 (max.)
From -55 to +75°C: ±2.0 (max.)
Resolution: 0.5°C
  • RoHS3 compliant
SPECTRUM100: Dracal USB connected Light sensor simultaneously detecting white light and colors, ultraviolet A and B, infrared and ambient light - Back view - Unique Serial Number SPECTRUM100: Dracal USB connected Light sensor simultaneously detecting white light and colors, ultraviolet A and B, infrared and ambient light - Front view
Learn more

SPECTRUM100

USB 5-band sensor for UVA, UVB, IR, RGB and ambient light
Ambient and white light
Range: 0.0072 to 120,000 lx
Resolution: 0.0036 lx per step
Colour and Infrared light
Range: 0 to 20,000 lx
Resolution: Up to 20 bits
Ultraviolet A and B light
UVA responsivity 0.93 counts/uW/cm2
UVB responsivity 2.1 counts/uW/cm2
Resolution: 16 bits (65,536 counts)
  • RoHS3 and CE compliant
USB-I2C-SPS30 - Dracal USB-connected adapter for Sensirion SPS30 particulate matter sensor - With SPS30 Sensirion Sensor USB-I2C-SPS30 - Dracal USB-connected adapter for Sensirion SPS30 particulate matter sensor - Front View
Learn more

USB-I2C-SPS30

USB adapter for SPS30 particulate matter sensor
General specifications
Communication: I2C to USB
I2C speed: 400 kHz
Operating temperature range: 0 to 70°C
Operating relative humidity range (non-condensing): 10 to 90 %RH
  • RoHS3 compliant
VOC100 - Dracal USB-connected as sensor volatile organic compound (VOC), temperature and relative humidity - Back view - Unique Serial Number VOC100 - Dracal USB-connected as sensor volatile organic compound (VOC), temperature and relative humidity - Front view with USB plug
Learn more

VOC100

USB VOC, temperature and relative humidity sensor
Typical operating range and precision
Volatile Organic Compounds (ppb): 0 to 32,768 Semi-Quantitative
Temperature (°C): -40 to 70 ±0.3
Relative humidity (%RH): 10 to 95 ±2.0
  • Monitors dew point
  • RoHS3 and CE compliant

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm
Dracal type K thermocouple probe exposed end for fast response temperature measurement
Learn more

Ready-made pre-wired thermocouple probe

Pre-wired type K, J, N, T, E thermocouple probes

Response time: ≤ 1 second
Available lengths: 1.5 m (5 ft) , 3 m (10 ft)
Insulation: Teflon
Type: Bare welded point
Temperature range Type dependent (See Charasteristics)
  • Compatible with Dracal Technologies TMC series thermocouple adapters
RTD_23: USB adapter for any Pt-100 RTD probe for temperature measurement - Back view - Unique Serial Number RTD_23: USB adapter for any Pt-100 RTD probe for temperature measurement - Front view
Learn more

RTD_23

2/3-wire RTD probe to USB connector (outdated)
This product is outdated and is supported for backward compatibility purposes only. If possible, consider the RTD223 instead.
Temperature
Operating range: -200 to 800°C
Accuracy (at 25°C): ±0.06°C
Resolution (typical): ±0.02°C
  • Supports 2 and 3-wire Pt100 RTD sensors
  • Temperature calculation using the DIN 43760 coefficients
  • RoHS3 compliant