Learn more
PTH200
All-in-one USB temperature sensor, with relative humidity and atmospheric pressure sensors
Typical operating range and precision
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificate
- RoHS 3 compliant


Learn more
PTH420
Precision USB Temperature, Relative Humidity and Atmospheric Pressure Sensor
Typical operating range and precision
Temperature | -40°C to 70°C | ±0.1°C |
Relative humidity | 0 %RH to 100 %RH | ±1.5 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


Learn more
PTH450
Robust, High Precision USB Temperature, Humidity and Air Pressure Sensor
Typical operating range and precision
Temperature | -40°C to 125°C | ±0.1°C |
Relative humidity | 0 %RH to 100 %RH | ±1.5 %RH |
Atmospheric pressure | 70 kPa to 110 kPa | ±0.15 kPa (at 25 °C) |
70 kPa to 110 kPa | ±0.18 kPa (from 10 to 40°C) | |
45 kPa to 110 kPa | ±0.20 kPa (from 0 to 40°C) |
Protection
- Internal filter efficiency: >99.99% of particles as small as 200 nm
- Compact aluminium external protection
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode option
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


Learn more
TRH450
Robust, high-precision USB temperature sensor with relative humidity
Typical operating range and precision
Temperature | -40°C to 125°C | ±0.1°C |
Relative humidity | 0 to 100 %RH | ±1.5 %RH |
Protection
- Internal filter efficiency: >99.99% of particles as small as 200 nm
- Compact aluminium external protection
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


Learn more
TRH420
Precision USB Temperature and Relative Humidity Sensor
Typical operating range and precision
Temperature | -40°C to 70°C | ±0.1°C |
Relative humidity | 0 to 100 %RH | ±1.5 %RH |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


Learn more
TRH320
USB Temperature and Relative Humidity Sensor
Typical operating range and precision
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Protection
- 2-layer filter
- Efficiency: >99.99% of particles as small as 200 nm
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant


Learn more
TRH200
USB Temperature and Relative Humidity Sensor With Exposed End
Typical operating range and precision
Temperature | -40°C to 70°C | ±0.3°C |
Relative humidity | 0 %RH to 100 %RH | ±2.0 %RH |
Protection
- Exposed sensor
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificate
- RoHS 3 compliant


Learn more
TMC200
High-precision and high-resolution USB adapter for thermocouples of type K, J, T, N, or E
Operating Range | Accuracy | |
TMC200k: | -200°C to 1372°C | ±0.5°C or better |
TMC200j: | -200°C to 1200°C | ±1.0°C or better |
TMC200t: | -200°C to +400°C | ±0.5°C or better |
TMC200n: | -200°C to +1300°C | ±0.5C or better |
TMC200e: | -200°C to +1000°C | ±0.5°C or better |
Resolution: | 0.01°C | |
Error status code: | Yes |
- Supports type-K/J/T/N/E thermocouples (2 or 3 pin)
- Built-in cold junction compensation
- Follows NIST ITS-90 thermocouple temperature correction table
Additional information
- Free data acquisition toolkit
- 3-point user calibration mechanism
- VCP mode
- Traceable to the CNRC (NIST) certificates
- RoHS 3 compliant