Selected filters

Categories

Show value(s)
PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Front view with USB Plug
Learn more

PTH200

All-in-one USB temperature sensor, with relative humidity and atmospheric pressure sensors
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificate
  • RoHS 3 compliant
Dracal_PTH420_Back_Unique_Serial_Number PTH420: USB-connected precision (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument (sensor) - Front view with cable
Learn more

PTH420

Precision USB Temperature, Relative Humidity and Atmospheric Pressure Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.1°C
Relative humidity 0 %RH to 100 %RH ±1.5 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
PTH450: Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument with USB connection, particle filter and aluminum tip for harsh environments.
Learn more

PTH450

Robust, High Precision USB Temperature, Humidity and Air Pressure Sensor
Typical operating range and precision
Temperature -40°C to 125°C ±0.1°C
Relative humidity 0 %RH to 100 %RH ±1.5 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminium external protection

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode option
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
RTD300: USB adapter for any Pt100 RTD probe for temperature measurement - With Pt100 probe RTD300: USB adapter for any Pt-100 RTD probe for temperature measurement - Front view - With connector
Learn more

RTD300

Enhanced Precision 2/3-wire RTD Probe to USB Adapter
Supports 2 and 3 wire PT100 RTD sensors
Temperature Operating range: -200°C to +800°C
Accuracy: ±0.005°C (at 25°C)
Accuracy: ±0.018°C (0°C to 50°C)
Resolution: ±0.0001°C (typical)
Noise level: ±0.0015°C ( at 25°C)
Drift: 0.007°C ±0.003°C/year (at 25°C and 45%RH)

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
BAR20 - Dracal USB-connected atmospheric pressure (barometer) sensor - Back view - Unique Serial Number BAR20 - Dracal USB-connected atmospheric pressure (barometer) sensor - Front view
Learn more

BAR20

USB Precision Barometer
Typical operating range and precision
Operating range 1 à 120 kPa (10 à 1200 mbar)
Accuracy ±0.15 kPa à 25°C (1.5 mbar)
Resolution 0.0065 kPa (0.065 mbar)

Internal temperature readings for compensation purposes

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor, particle filter and aluminum tip for harsh environments - Front view with USB plug TRH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor, particle filter and aluminum tip for harsh environments - Front View with cable.
Learn more

TRH450

Robust, high-precision USB temperature sensor with relative humidity
Typical operating range and precision
Temperature -40°C to 125°C ±0.1°C
Relative humidity 0 to 100 %RH ±1.5 %RH

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminium external protection

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH420: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor - Front View with cable. TRH420: Improved accuracy (±0.1°C/±1.5 %RH) temperature and relative humidity USB sensor - Front View with USB plug
Learn more

TRH420

Precision USB Temperature and Relative Humidity Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.1°C
Relative humidity 0 to 100 %RH ±1.5 %RH

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH320: Temperature and relative humidity USB sensor - Front view TRH320: Temperature and relative humidity USB sensor - Front View with USB plug
Learn more

TRH320

USB Temperature and Relative Humidity Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
TRH200: USB Temperature and Relative Humidity Sensor With Exposed End - Zoomed End TRH200: USB Temperature and Relative Humidity Sensor With Exposed End - USB Plug and End
Learn more

TRH200

USB Temperature and Relative Humidity Sensor With Exposed End
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH

Protection

  • Exposed sensor

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificate
  • RoHS 3 compliant