Selected filters

Categories

Show value(s)
PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH200 - Dracal USB temperature, relative humidity and atmospheric pressure sensor - Front view with USB Plug
Learn more

PTH200

All-in-one USB temperature sensor, with relative humidity and atmospheric pressure sensors
Typical operating range and precision
Temperature -40°C to 70°C ±0.3°C
Relative humidity 0 %RH to 100 %RH ±2.0 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificate
  • RoHS 3 compliant
Dracal_PTH420_Back_Unique_Serial_Number PTH420: USB-connected precision (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument (sensor) - Front view with cable
Learn more

PTH420

Precision USB Temperature, Relative Humidity and Atmospheric Pressure Sensor
Typical operating range and precision
Temperature -40°C to 70°C ±0.1°C
Relative humidity 0 %RH to 100 %RH ±1.5 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Protection

  • 2-layer filter
  • Efficiency: >99.99% of particles as small as 200 nm

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant
PTH450: Dracal USB temperature, relative humidity and atmospheric pressure sensor - Back View - Unique Serial Number PTH450: Improved accuracy (±0.1°C/±1.5 %RH) temperature, relative humidity and atmospheric pressure measuring instrument with USB connection, particle filter and aluminum tip for harsh environments.
Learn more

PTH450

Robust, High Precision USB Temperature, Humidity and Air Pressure Sensor
Typical operating range and precision
Temperature -40°C to 125°C ±0.1°C
Relative humidity 0 %RH to 100 %RH ±1.5 %RH
Atmospheric pressure 70 kPa to 110 kPa ±0.15 kPa (at 25 °C)
70 kPa to 110 kPa ±0.18 kPa (from 10 to 40°C)
45 kPa to 110 kPa ±0.20 kPa (from 0 to 40°C)

Protection

  • Internal filter efficiency: >99.99% of particles as small as 200 nm
  • Compact aluminium external protection

Additional information

  • Free data acquisition toolkit
  • 3-point user calibration mechanism
  • VCP mode option
  • Traceable to the CNRC (NIST) certificates
  • RoHS 3 compliant